UV Systems
UV systems will protect you from living organisms in your water such as bacteria and cysts. Ultraviolet (UV) water purification systems are trusted by thousands of people worldwide for use in homes, cottages, and in many industrial and commercial applications. UV systems come in a variety of sizes and can be used to purify the water for a single faucet or for an entire home or larger building. UV systems are superior to chemical water disinfection because they don't add any harmful chemicals to the water, or to the environment.

MICRO – BIOLOGICAL PROBLEM IN VARIOUS INDUSTRIES:

Pharmaceuticals Industry : # Bacterial count in process water.
                                           # Bacterial growth in sand filter, Carbon filter, D.M. Plant.
                                           # Decreased shelf life of the R.O. Membrane, Resin & Filter beds etc.
Bottling Industry             : # Decreased shelf life of the end mineral water, Soft Drink, product.
Dairy Canneries              : # Contamination of bottles.
                                          # Bacterial growth in Sand filter, Carbon filter, D.M.Plant.
Food & Beverage Industry : # Decreased shelf life of the end product.
Fish Hatcheries                : # Whirling disease.
                                          # Increased fish mortality.
Paint Industry  :                 # Decreased shelf life of the water based paints.
Poultry Industry :              # Increased bird mortality. 

Specification:

  1. Ultra violet radiation is  natural source of purification.
  2. Ultra violet radiation band of invisible light in the electromagnetic spectrum, in the range of 200 – 400 nm wavelengths.
  3. The U.V. wavelength of 253.7 nm possesses the greatest germicidal effectiveness, which Penetrate the microbial cell membrane to destroy the DNA molecule thus preventing cell Replication.
  4. U.V. is used to provide Bacterial Disinfection in water. It does not change the Physical or Chemical Characteristics in water. U.V. provides disinfection On Contact. It does not have any residual properties left in treated water.
  5. Special High Germicidal Lamps produce high U.V. output in 254 nm range.
  6. There are no know micro organisms resistant to U,V,
  7. U.V. water purification is preferred the world over because it is the simplest & most practical means of destroying micro organisms in water.

CONVENTIONAL METHODS OF WATER TREATING

 

CHLORINE

OZONE

ULTRA VIOLET

Capital cost

Lowest

High

Low

Ease of installation

Good

Poor

Excellent

Ease of Maintenance

Good

Poor

Excellent

Cost of Maintenance

Medium

High

Lowest

Operating Cost

Low

High

Low

Frequency Of Maintenance

Frequent

Continuous

V. Infrequent

Control System

Poor

Good

Excellent

Virucidal Effect

Good

Poor

Good

Toxic Chemical

Yes

Yes

No

Residual Effect Problem with

Yes

Yes

No

Hazards

High

Yes

Low to none

Contact Time

30 - 60 minutes

High

1 – 5seconds

Disinfection Performance

Leaves some pathogens

Kills all microbes

Kills all microbes

Effect on Water

Organochlorine compounds, Taste & pH changes

Unknown

None

The Ultra violet dose required for destruction is about the same for each virus, while higher dose of chlorine & ozone needed.

                                      

MIROBIAL STANDARDS FOR DRINKING WATER

Test

W.H.O.

U.S.P.H.A.

SWE Standard

Total Bacterial Count

Test not specified

500 organisms/ml.

Les than 500 organisms/ml.

Coli form

95% of sample should not coli forms & maximum 10 coliforms/100ml.

95% of sample should not contain coli form

NIL ( Coli forms )

E-Coli

No E.Coli in 100ml.

No E.Coli in 100ml.

NIL ( E. Coli )



SR.NO

FLOW RATE /HRS

MODEL NO

INLET & OUTLET

NO.UV LAMP &
Q .JACKET

POWER( WATTS)

1.

150 LPH

SWE - 1

½” THRD

1

8

2.

250 LPH

SWE - 2

½”  BSP

1

16

3.

500 LPH

SWE – 2X2

¾” BSP

2

16

4.

750 LPH

SWE 4X2

¾” BSP

2

32

5.

1500 LPH

SWE 8

¾” BSP

1

39

6.

3000 LPH

SWE 16

1” BSP/25 NB

2

80

7.

5000 LPH

SWE 50

1.5” BSP /40 NB

3

120

8.

7500 LPH

SWE -32

1.5” BSP / 40 NB

4

160

9.

8 m3 – 10 m3

SWE – 100

2”BSP/50 NB

6

240

10.

12 m3 – 15 m3

SWE – 150

2”BSP/50 NB

8

320

11.

20 m3 – 25 m3

SWE – 250

( 2 Chamber ) 50NB

12

480

12.

30 m3 – 35 m3

SWE - 350

( 2 Chamber ) 50NB

16

640

13

40 m3 – 45 m3

SWE – 450

( 3 Chamber ) 80NB

18

720

14

55 m3 – 65 m3

SWE – 650

( 4 Chamber ) 80NB

24

960

Main Feature:

  1. U.V. Chamber S.S. 316 electropolished purification chamber for life time corrosion free service.
  2. High intensity U.V. lamp of continuously use. ( Imported )
  3. Quick lamp change in less than a minute without shut down of water pressure or drainage of chamber.
  4. Lamp Monitor indicates functioning of the U.V lamp
  5. Quartz jackets silica used for its proven capability of 99% transmitting maximum  Ultra Violet rays  for peak  Ultra Violet dosage 30,000 uW  sec / cm2 .
  6. Wiper Assembly facilities periodic cleaning of quartz glass to ensure peak efficiency without interruption of purifier operation
  7. Working pressure maximum 3.5 kg/ cm2 or gravity.
  8. Continuously 24 hours use. Operating expenses of less than one paisa per 10 liters of purified water.
  9. Removable Flange Heads for easy and complete disassembly  without use of special tools.

OPTIONAL ACCESSORIES :

  1. Time Elapse Meter for identification of  U.V lamp life utilized
  2. Optional Prefilter for cloudy water or filtration systems .
  3. Ultraviolet Monitor to sense and indicate the level of germicidal U.V  dosage  30,000 uW sec / cm2  

QUALITY CONTROL:

Every U.V lamp & Quartz jacket Silica individually checked and each completed
System tested and run before dispatch

Check Stainless steel & silicon material i.e. Gasket, ‘o’ Ring with Validation certificates.
                        
Our comprehensive after sales service includes a full range of spares and professional technical backup, with an optional Annual Maintenance Contract in all over India.